Mfg Part Number: 154911 | NSN : 5950-00-259-5774 |
NIIN : 002595774 | CAGE Code : 56200 |
Manufacturer: Tymshare Inc | Item Name : Transformer Power |
FSC : 5950 Coils and Transformers |
Thank you for your interest in 154911 part number. At ASAP Domain 360, we offer an unparalleled inventory of premium NSN components. 154911 part is listed with the description of Transformer Power, along with the NSN 5950-00-259-5774. ASAP Domain 360 has a strict No-China Sourcing pledge, and we only stock our NSN parts from reliable manufacturers like Tymshare Inc. If you are interested in initiating the purchasing process for 154911 part, please fill out and submit the Instant RFQ form provided below. Upon receiving your request, an account manager will contact you in 15 minutes or less with a personalized quotation for comparison.
ASAP Domain 360 offers many high-quality NSN parts available for immediate purchase. A National Stock Number (NSN) is a numeric code used to classify components manufactured, bought, and sold in the federal supply system. Each NSN is unique, and the various numbers can be used to describe qualities like the item's country of origin and federal supply class. This system is used by the United States DOD and every other NATO-allied nation to eliminate confusion and the duplication of orders. At ASAP domain, finding your required NSN part is simple. Furthermore, this component, 5950-00-259-5774, is also listed with its CAGE Code 56200 belonging to Tymshare Inc for ease of search.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-259-5774 Item Description: Transformer Power | 5950 | 002595774 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
154911 | 6 | 1 | C | A |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHEDNOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 8.062 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP8.062 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 4.375 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP4.375 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ACZB | FREQUENCY RATING | 50.0 HERTZ MINIMUM SINGLE COMPONENT AND 50.0 HERTZ MINIMUM SINGLE COMPONENT AND 60.0 HERTZ MAXIMUM SINGLE COMPONENT60.0 HERTZ MAXIMUM SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENTSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO CORE AND BROUGHT OUT TO TERMINAL SINGLE COMPONENTINTERNAL SHIELD GROUNDED TO CORE AND BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
ADAQ | BODY LENGTH | 8.500 INCHES NOMINAL8.500 INCHES NOMINAL |
ADAT | BODY WIDTH | 6.500 INCHES MAXIMUM6.500 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 5.540 INCHES NOMINAL5.540 INCHES NOMINAL |
AKNA | INCLOSURE TYPE | PARTIALLY INCLOSED, DOUBLE SHELLPARTIALLY INCLOSED, DOUBLE SHELL |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP4 SINGLE GROUP |
AXGY | MOUNTING METHOD | THREADED HOLE SINGLE GROUPTHREADED HOLE SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 PRIMARY SINGLE COMPONENT AND 9 SECONDARY SINGLE COMPONENT9 SECONDARY SINGLE COMPONENT |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 2.0 AMPERES DC MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 20.0 AMPERES DC MAXIMUM SINGLE COMPONENT 3RD SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 30.0 AMPERES DC MAXIMUM SINGLE COMPONENT 2ND SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 6.0 AMPERES DC MAXIMUM SINGLE COMPONENT 4TH SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 4.00 DC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY25.00 DC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY8.00 DC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 4.00 DC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY44.00 DC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 44.00 DC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 44.00 DC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY8.00 DC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY4.00 DC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 8.00 DC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY25.00 DC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY120.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY AND 127.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
TTQY | TERMINAL TYPE AND QUANTITY | 26 WIRE LEAD |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
We Hope that You Will Visit Us Again the Next Time You Need NSN Parts and Make Us Your Strategic Purchasing Partner.
Request for Quote